If you’re a spec engineer, plant manager, or operations lead working with medium voltage (MV) electrical infrastructure—whether you’re specifying new switchgear, upgrading an existing substation, or troubleshooting a persistent system disturbance—you’ve almost certainly heard the term “surge arrester” tossed around. But if you’re like many MV stakeholders, you might still be wondering: What exactly does it do? Why does it matter so much for the switchgear I’m investing in? And as a long-time MV switchgear supplier, I’m here to tell you that this small, often overlooked component is one of the most critical lines of defense your system has. Let’s break this down, no overly technical jargon, just real-world context from 18 years in this business. Medium Voltage Switchgear

First, let’s ground this in what MV switchgear is, for anyone new to the space. MV switchgear is the collection of electrical devices—breakers, disconnects, fuses, busbars, relays—that control, protect, and isolate electrical equipment operating between 1 kV and 35 kV. This is the sweet spot for commercial buildings, manufacturing plants, mining sites, and rural substations that deliver power to smaller loads, and it’s designed to keep power flowing safely while preventing faults from spreading. But even the most well-built switchgear can’t handle sudden, massive spikes in voltage—called surges or transients—that hit the system unexpectedly. That’s where surge arresters come in.
So what is a surge arrester, exactly? Put simply, it’s a protective device mounted directly onto switchgear (or adjacent to it) that diverts dangerous voltage surges to the ground, safely, so they don’t damage sensitive components like circuit breakers, transformers, or relays. Think of it like a pressure relief valve for your home’s plumbing: if water pressure spikes too high, the valve opens to release excess pressure before pipes or fixtures break. That’s the core function, but there’s a lot more nuance that makes the difference between a switchgear system that lasts 20 years and one that’s out of commission after a single lightning strike.
Let’s talk about where those surges come from, because that’s why this matters so much. There are two main types of surges we deal with in MV systems: external and internal. External surges are the big, dramatic ones—lightning strikes. When lightning hits a power line, a building’s roof, or even a nearby tree, it sends a massive, short-duration voltage spike (hundreds of thousands of volts, sometimes millions) racing through the electrical system. If that spike hits your switchgear, it can melt insulation, weld breaker contacts shut, or fry internal relays in milliseconds—damage that takes days or weeks to repair, which translates to lost production time and big repair bills. Last year, we worked with a food processing plant in Ohio that skipped installing surge arresters when they upgraded their 12 kV switchgear. A nearby thunderstorm knocked out their main breaker and two motors, costing them $120,000 in downtime in just three days. That’s not an edge case; it’s why every MV system needs these devices.
Internal surges are less flashy, but just as common, especially in industrial settings. They come from things like switching operations—when a circuit breaker flips on or off, it causes a temporary voltage spike. Or from faults in the system, like a tree falling on a power line or a short circuit. For example, a plant that runs large induction motors will see switching surges every time they start or stop a motor, and over time, those repeated small spikes wear down insulation on busbars and breakers, leading to premature failure. That’s where surge arresters earn their keep even when there’s no lightning—they shorten those internal surges and limit their amplitude, so they don’t accumulate damage over years of operation.
Now, not all surge arresters are created equal, especially when paired with MV switchgear. We’ve seen this firsthand over the years. The most common type used in modern MV switchgear is the metal-oxide varistor (MOV) arrester, which replaced older silicon carbide types in the 1980s because they’re more efficient at diverting surges without interrupting normal power flow. Unlike a fuse, which works once and needs replacing, a properly rated MOV arrester is designed to withstand hundreds of surge events over its lifespan, as long as it’s matched to your switchgear’s voltage class.
Wait—matched is the key word here. A common mistake we see new customers make is buying a generic surge arrester that works for 15 kV systems and slapping it on a 12 kV switchgear setup, or vice versa. That’s a recipe for failure. Surge arresters are rated for a specific maximum continuous operating voltage (MCOV), which has to be higher than the normal operating voltage of your switchgear. If it’s too low, it will start conducting power during normal operation, causing heat buildup and early failure. If it’s too high, it won’t divert surges effectively, leaving your system unprotected. It’s like using a garden hose for a fire hydrant—even if you point it at a flame, it won’t put it out.
Another critical factor: the discharge current rating of the arrester. This is how much current it can safely divert during a major surge. For a switchgear installation near overhead power lines, you need a higher discharge current rating than for a switchgear setup buried indoors or underground, where lightning strikes are less common. When we quote MV switchgear to a customer, we don’t just send them a generic box—we tailor the surge arresters to their specific environment. A mine in Wyoming, where lightning is frequent and operating voltages are 25 kV, gets a different arrester than a university campus in Illinois with a 12 kV system buried mostly underground. That’s the kind of detail that separates a supplier who just sells equipment from one who actually understands how to keep your system running.
We’ve also learned over the years that where you mount the surge arrester on the switchgear matters just as much as the arrester itself. The ideal location is as close as possible to the components you’re protecting—usually near the main busbars, or right before sensitive equipment like transformers or VFDs (variable frequency drives). Why? Because surge voltages drop off slightly the farther they travel, so an arrester mounted 10 feet away from a breaker might not divert enough of the surge to protect that breaker. Last year, we worked with a utility company that was having repeated breaker failures in their 15 kV switchgear. They had installed surge arresters, but they mounted them 20 feet away from the breakers, near the main incoming line. Moving the arresters right next to the breakers cut their failure rate by 90% in six months. That’s the kind of on-the-ground data we use every day to inform our designs.
Another question we get all the time: How long do surge arresters last, and how do I know when to replace them? There’s no universal answer, because it depends on how many surge events they’ve seen, their operating environment, and their quality. A high-quality MOV arrester used in a low-stress indoor environment might last 20 to 25 years, while one in a lightning-prone outdoor setting might need replacement every 10 to 15 years. That’s why regular predictive maintenance is important. Modern surge arresters have diagnostic features that let you test for leakage current without taking the switchgear out of service—no need for costly shutdowns to check if your protection is working. That’s a feature we include in most of our switchgear packages now, because our customers don’t want downtime just to check a component that’s supposed to prevent downtime.
Let’s circle back to why this matters for you, the MV switchgear stakeholder. When you invest in new switchgear, you’re looking at a big capital expense—often tens or hundreds of thousands of dollars. The last thing you want is for that investment to be damaged or destroyed by a surge that could have been prevented with a properly selected and installed surge arrester. We had a customer last year who skipped adding surge arresters to a new 20 kV switchgear installation for a chemical plant. A month after they powered it on, a minor switching surge from the grid caused a relay to fail, which then caused a secondary fault in the switchgear’s busbars. The total repair and downtime cost them $320,000—more than the entire cost of adding surge arresters to their initial order. That’s the math no one wants to do, and it’s exactly why we include surge arrester specification as a core part of our switchgear design process.
It’s also worth noting that modern codes and standards are getting stricter around surge protection for MV systems. The Institute of Electrical and Electronics Engineers (IEEE) has set standards for surge arrester performance and installation, and most national electrical codes now require surge arresters for MV switchgear installations over a certain voltage. That’s not a arbitrary rule—its based on decades of data showing that properly installed surge arresters reduce electrical failures by more than 75% in MV systems. As a supplier, we don’t just meet the minimum standards; we go above them, because we’ve seen firsthand what happens when systems are underprotected.
Let’s bust a couple of common myths while we’re at it. The first myth: Surge arresters only protect against lightning. No—we already mentioned internal surges from switching operations and faults, but another big one is switching surges on overhead lines, which happen every time a utility flips a main breaker on or off. Those surges might not be as big as lightning, but they happen thousands of times a year, and repeated exposure leads to insulation degradation over time. The second myth: Bigger surge arresters are better. Not at all—we’ve seen customers buy the highest discharge current arresters available for their low-stress indoor systems, which is not only a waste of money, but can actually lead to worse performance if the MCOV is mismatched. It’s all about matching the arrester to your specific system, environment, and needs.
At the end of the day, surge arresters are one of those components that are easy to ignore when everything is running smoothly, but when they do their job right, you never even notice them. That’s exactly what we build our business on: making sure our MV switchgear is reliable, protected, and designed to keep your power flowing, no matter what throws at it. Whether you’re building a new substation, upgrading an existing switchgear setup, or troubleshooting a persistent issue that’s costing you production, the right surge arrester paired with the right switchgear makes all the difference.

If you’re currently in the market for medium voltage switchgear, or if you have questions about whether your existing system’s surge protection is up to par, we’re here to help. We don’t just sell equipment—we work with you to design a solution tailored to your specific needs, taking into account your operating voltage, environment, load types, and budget. A quick conversation with our team can help you avoid costly downtime, prevent premature equipment failure, and make sure your power system is protected for years to come. Don’t wait until a surge hits—reach out to us today to discuss your MV switchgear and surge protection needs.
Outdoor Prefabricated Substation References
IEEE Std C62.11, Standard for Metal-Oxide Surge Arresters for AC Power Circuits (>1 kV)
IEEE Std 1584, Guide for Performing Arc-Flash Hazard Calculations
ANSI C12.1, Electricity Meters – Specification